BIOTIN INTERFERENCE IN THYROID FUNCTION AND CARDIAC TROPONIN ASSAYS

Authors

  • Bruna Rafaela Bepler
  • Fábio Costa do Nascimento
  • Tainá Pinto de Lima
  • Tarik Rugai Salle
  • Manuela Assis da Escóssia Fernandes
  • Julia Biagi Utuari da Silva
  • Ana Julia Yukari Tokuno

DOI:

https://doi.org/10.56238/revgeov17n10-038

Keywords:

Biotin, Immunoassay Interference, Thyroid Function Tests, Cardiac Troponin, Laboratory Medicine, Patient Safety

Abstract

Biotin is present in common over-the-counter supplements and is also used at pharmacologic doses, but circulating biotin can interfere with immunoassays that depend on streptavidin–biotin capture. The direction and magnitude of error are determined by assay architecture, analyte, reagent generation, circulating concentration, and time from ingestion to sampling. This integrative review examined PubMed-indexed analytical studies, controlled ingestion studies, prevalence cohorts, case reports, and professional guidance addressing thyroid-related and cardiac troponin testing. In susceptible competitive thyroid assays, excess biotin commonly produces falsely increased results, whereas susceptible sandwich assays commonly produce falsely decreased results. The resulting combination of low thyroid-stimulating hormone and high free thyroid hormones can mimic hyperthyroidism and has caused diagnostic and therapeutic errors. Cardiac troponin is generally measured by sandwich immunoassay; interference can therefore lower the reported concentration and, in a time-critical setting, create false reassurance. Nevertheless, risk is not uniform across cardiac troponin T and I platforms, and newer reagent generations may tolerate substantially greater biotin concentrations. A reported dose alone cannot define safety because supplement formulation, timing, repeated exposure, renal clearance, and platform-specific thresholds differ. Recognition should begin with an explicit supplement history and assessment of clinical–laboratory discordance. Confirmation may require recollection after an appropriate interval, measurement on a method with different architecture, direct biotin measurement, or a locally validated depletion procedure. Universal washout rules and unvalidated numerical correction should be avoided. Effective prevention depends on coordinated communication among clinicians, laboratories, manufacturers, and patients, with special attention to thyroid panels and acute coronary syndrome pathways.

Downloads

Download data is not yet available.

References

1. Li D, Ferguson A, Cervinski MA, Lynch KL, Kyle PB. AACC Guidance Document on Biotin Interference in Laboratory Tests. J Appl Lab Med. 2020;5(3):575-587. DOI: https://doi.org/10.1093/jalm/jfz010

2. Dasgupta A. Immunoassay design and biotin interference. Adv Clin Chem. 2022;109:165-183. DOI: https://doi.org/10.1016/bs.acc.2022.03.005

3. Favresse J, Burlacu MC, Maiter D, Gruson D. Interferences With Thyroid Function Immunoassays: Clinical Implications and Detection Algorithm. Endocr Rev. 2018;39(5):830-850. DOI: https://doi.org/10.1210/er.2018-00119

4. Ylli D, Soldin SJ, Stolze B, Wei B, Nigussie G, Nguyen H, et al. Biotin Interference in Assays for Thyroid Hormones, Thyrotropin and Thyroglobulin. Thyroid. 2021;31(8):1160-1170. DOI: https://doi.org/10.1089/thy.2020.0866

5. Li D, Radulescu A, Shrestha RT, Root M, Karger AB, Killeen AA, et al. Association of Biotin Ingestion With Performance of Hormone and Nonhormone Assays in Healthy Adults. JAMA. 2017;318(12):1150-1160. DOI: https://doi.org/10.1001/jama.2017.13705

6. Zhang Y, Wang R, Dong Y, Huang G, Ji B, Wang Q. Assessment of biotin interference in thyroid function tests. Medicine (Baltimore). 2020;99(9):e19232. DOI: https://doi.org/10.1097/MD.0000000000019232

7. Trambas C, Lu Z, Yen T, Sikaris K. Characterization of the scope and magnitude of biotin interference in susceptible Roche Elecsys competitive and sandwich immunoassays. Ann Clin Biochem. 2018;55(2):205-215. DOI: https://doi.org/10.1177/0004563217701777

8. Li J, Wagar EA, Meng QH. Comprehensive assessment of biotin interference in immunoassays. Clin Chim Acta. 2018;487:293-298. DOI: https://doi.org/10.1016/j.cca.2018.10.013

9. Piketty ML, Prie D, Sedel F, Bernard D, Hercend C, Chanson P, et al. High-dose biotin therapy leading to false biochemical endocrine profiles: validation of a simple method to overcome biotin interference. Clin Chem Lab Med. 2017;55(6):817-825. DOI: https://doi.org/10.1515/cclm-2016-1183

10. Elston MS, Sehgal S, Du Toit S, Yarndley T, Conaglen JV. Factitious Graves' Disease Due to Biotin Immunoassay Interference-A Case and Review of the Literature. J Clin Endocrinol Metab. 2016;101(9):3251-5. DOI: https://doi.org/10.1210/jc.2016-1971

11. Barbesino G. Misdiagnosis of Graves' Disease with Apparent Severe Hyperthyroidism in a Patient Taking Biotin Megadoses. Thyroid. 2016;26(6):860-3. DOI: https://doi.org/10.1089/thy.2015.0664

12. Odhaib SA, Mansour AA, Haddad NS. How Biotin Induces Misleading Results in Thyroid Bioassays: Case Series. Cureus. 2019;11(5):e4727. DOI: https://doi.org/10.7759/cureus.4727

13. Katzman BM, Lueke AJ, Donato LJ, Jaffe AS, Baumann NA. Prevalence of biotin supplement usage in outpatients and plasma biotin concentrations in patients presenting to the emergency department. Clin Biochem. 2018;60:11-16. DOI: https://doi.org/10.1016/j.clinbiochem.2018.07.004

14. Gunsolus IL, Matias M, Prostko J, Mohr P, Sokoll LJ. Prevalence of Detectable Biotin in Five US Emergency Department Patient Cohorts. Clin Biochem. 2021;93:26-32. DOI: https://doi.org/10.1016/j.clinbiochem.2021.03.009

15. Sanders A, Gama R, Ashby H, Mohammed P. Biotin immunoassay interference: A UK-based prevalence study. Ann Clin Biochem. 2021;58(1):66-69. DOI: https://doi.org/10.1177/0004563220961759

16. Paketçi A, Köse E, Gürsoy Çalan Ö, Acar S, Teke P, Demirci F, et al. Serum Level of Biotin Rather than the Daily Dosage Is the Main Determinant of Interference on Thyroid Function Assays. Horm Res Paediatr. 2019;92(2):92-98. DOI: https://doi.org/10.1159/000502740

17. Nguyen KQN, Langevin R, Fankhauser K, Hashim IA. Assessment of Risk for Interference by Circulating Biotin in Samples Received for High Sensitivity Troponin-T, Thyrotropin, and for Prostate Specific Antigen Testing by Immunoassays. Clin Lab. 2020;66(1). doi: 10.7754/Clin.Lab.2019.190642. DOI: https://doi.org/10.7754/Clin.Lab.2019.190642

18. Frame IJ, Joshi PH, Mwangi C, Gunsolus I, De Lemos JA, Das SR, et al. Susceptibility of Cardiac Troponin Assays to Biotin Interference. Am J Clin Pathol. 2019;151(5):486-493. DOI: https://doi.org/10.1093/ajcp/aqy172

19. Schrapp A, Fraissinet F, Hervouet C, Girot H, Brunel V. Biotin and high-sensitivity cardiac troponin T assay. Biochem Med (Zagreb). 2018;28(3):030901. DOI: https://doi.org/10.11613/BM.2018.030901

20. Saenger AK, Jaffe AS, Body R, Collinson PO, Kavsak PA, Lam CSP, et al. Cardiac troponin and natriuretic peptide analytical interferences from hemolysis and biotin: educational aids from the IFCC Committee on Cardiac Biomarkers (IFCC C-CB). Clin Chem Lab Med. 2019;57(5):633-640. DOI: https://doi.org/10.1515/cclm-2018-0905

21. Mumma B, Diercks D, Twerenbold R, Valcour A, Ziegler A, Schützenmeister A, et al. Clinical risk assessment of biotin interference with a high-sensitivity cardiac troponin T assay. Clin Chem Lab Med. 2020;58(11):1931-1940. DOI: https://doi.org/10.1515/cclm-2019-0962

22. Mzougui S, Favresse J, Soleimani R, Fillée C, Gruson D. Biotin interference: evaluation of a new generation of electrochemiluminescent immunoassays for high-sensitive troponin T and thyroid-stimulating hormone testing. Clin Chem Lab Med. 2020;58(12):2037-2045. DOI: https://doi.org/10.1515/cclm-2020-0214

23. von Meyer A, Albert G, Kunzelmann S, Rank C, Zerback R, Imdahl R. Evaluating the performance of an updated high-sensitivity troponin T assay with increased tolerance to biotin. Clin Chem Lab Med. 2021;59(3):591-597. DOI: https://doi.org/10.1515/cclm-2020-0104

24. Harley K, Bissonnette S, Inzitari R, Schulz K, Apple FS, Kavsak PA, et al. Independent and combined effects of biotin and hemolysis on high-sensitivity cardiac troponin assays. Clin Chem Lab Med. 2021;59(8):1431-1443. DOI: https://doi.org/10.1515/cclm-2021-0124

25. Bevins NJ, Hubbard JA, Fitzgerald RL, Kelner MJ. A Dilution Method to Mitigate Biotin Interference in Cardiac Troponin T Testing. J Appl Lab Med. 2019;4(3):415-421. DOI: https://doi.org/10.1373/jalm.2018.028589

26. Gifford JL, de Koning L, Sadrzadeh SMH. Strategies for mitigating risk posed by biotin interference on clinical immunoassays. Clin Biochem. 2019;65:61-63. DOI: https://doi.org/10.1016/j.clinbiochem.2018.12.007

27. Bowen R, Benavides R, Colón-Franco JM, Katzman BM, Muthukumar A, Sadrzadeh H, et al. Best practices in mitigating the risk of biotin interference with laboratory testing. Clin Biochem. 2019;74:1-11. DOI: https://doi.org/10.1016/j.clinbiochem.2019.08.012

28. Moerman A, Delanghe JR. Sense and nonsense concerning biotin interference in laboratory tests. Acta Clin Belg. 2022;77(1):204-210. DOI: https://doi.org/10.1080/17843286.2020.1780770

29. Mrosewski I, Urbank M, Stauch T, Switkowski R. Interference From High-Dose Biotin Intake in Immunoassays for Potentially Time-Critical Analytes by Roche. Arch Pathol Lab Med. 2020;144(9):1108-1117. DOI: https://doi.org/10.5858/arpa.2019-0425-OA

30. Colon PJ, Greene DN. Biotin Interference in Clinical Immunoassays. J Appl Lab Med. 2018;2(6):941-951. DOI: https://doi.org/10.1373/jalm.2017.024257

31. Chiu KC, Jhan JR, Yan HN, Liao YC, Lu WH, Lee KY, et al. Biotin interference in routine clinical immunoassays. Pract Lab Med. 2025;45:e00472. DOI: https://doi.org/10.1016/j.plabm.2025.e00472

Published

2026-10-08

How to Cite

Bepler, B. R., do Nascimento, F. C., de Lima, T. P., Salle, T. R., Fernandes, M. A. da E., da Silva, J. B. U., & Tokuno, A. J. Y. (2026). BIOTIN INTERFERENCE IN THYROID FUNCTION AND CARDIAC TROPONIN ASSAYS. Revista de Geopolítica, 17(10), e3637. https://doi.org/10.56238/revgeov17n10-038

Most read articles by the same author(s)

Similar Articles

1-10 of 50

You may also start an advanced similarity search for this article.